The admin command is 'upgrade hw-module fpd rommona location all'. RP/0/RP0/CPU0:CRS-E(admin)# upgrade hw-module fpd rommona location all Fri Feb 13 09:59:18.961 PST PDT% RELOAD REMINDER: - The upgrade operation of the target module will not interrupt its normal operation. Symptom: The command does not display by 'show run' when reload switch, But I can find it by 'show start-'. hw-module slot x account np 0 out 24 hw-module slot x account np 1 out 24 - Problem description/Trigger: - command 'hw-module slot account np in/out' and 'hw-module slot allow-coexist np ' gets removed when first. Hw Module Slot R0 Reload During Hw Module Slot R0 Reload free spins, you can also benefit from extra multipliers. In some titles, you can only land high-paying symbols during free spins, which is fantastic. All Hw Module Slot R0 Reload these perks make free spins a brilliant opportunity to make some amazing profits! To power off a particular module, use Switch(config)# no hw-module module num power; you can find that command on Page 20 of this Cisco doc. FYI, there isn't a graceful shutdown command for the whole switch. You should backup your config (just in case), issue a reboot, wait till you can audibly hear a change in fan speed, and then remove.

  1. Hw-module Slot Reloading Equipment
  2. Hw-module Slot Reloading Bullets
  3. Hw-module Slot Reloading
  4. Hw-module Slot Reloaded
I learned something interesting about the cisco ASA 5558-X chassis & that I thought was interesting;
Please reference this image from cisco website of a typical 5558-X chassis.
http://www.cisco.com/c/en/us/td/docs/security/asa/hw/maintenance/5585guide/5585Xhw/overview.html#pgfId-1100238
The hw-module slot1 which encompass the IPS also carries the GIGE interfaces gi 1/0-7 and the 10GIGE interfaces as well 1/8-9.
Shutting down the hw-module slot1 will 'DROP' all interfaces in slot1 and not just the IPS modules.
Take a look at these show outputs;

And the available hardware module commands

1: So the meer issuing of a hw-module #1 shutdown, actually shutdown the whole slot1 and NOT just the IPS


2: A issuing of a hw-module #1 reload, will not disturb any GIGE interfaces on slot#1
I found this interesting while diagnostic and debugging a buggy IPS module. I have a case open with TAC over these issues. They are looking into it a trying to determine if this is normal behavior.
Hw-module slot reloading
I found it funny cisco won't let you shutdown slot#0, but they allow slot#1 , and it will bring all interfaces on that slot down including the IPS module that I was trying to trouble shoot.
http://socpuppet.blogspot.com/2015/01/asa-ips-modules-reloads-732-e4.html
Ken Felix
Freelance Network/Security Engineer
Hw-module
I found it funny cisco won't let you shutdown slot#0, but they allow slot#1 , and it will bring all interfaces on that slot down including the IPS module that I was trying to trouble shoot.
http://socpuppet.blogspot.com/2015/01/asa-ips-modules-reloads-732-e4.html
Ken Felix
Freelance Network/Security Engineer
kfelix -----a----t---- socpuppets ---dot---com